Alert message templates for Canadian SCADA, IT and building alarms
These alert message templates give you short, clear wording for the alarms teams text most. Each one says where, what, how bad and when, and fits in a single text. Copy a line, swap the parts in angle brackets for your own names and metric values, and paste it into your system's alert email.
7-day free trial, 15 message creditsCard required for verificationNo charge for 7 daysEmail reminder before billing
Published:
What these templates are for
Most alarm systems let you edit the subject or message of their alert email. That wording is what ends up on the on-call phone. A few minutes spent on it saves a confused call at night. It sits alongside the on-call sheet in our SMS alert templates.
Each line below is shown as the finished text. The part between Welco: and the opt-out line is what your system should send. Keep that middle part under about 130 plain characters so the whole text fits in one 160-character segment.
How each template is built
Every line follows the same order. First comes a short tag in square brackets, then the fault in a few words, a value if there is one, and the time. The tag shows first on a lock screen, so the reader knows where to go before opening the text.
Square brackets are worth their cost, but they are not free. Each bracket counts as two characters in a plain text, so a tag like [Lift 4] uses ten. Upper case words like FAIL or HIGH HIGH mark the state without any symbols.
SCADA and water alarm templates
For pump stations, tanks, wells and treatment plants. Put the site first, because that's where the operator drives.
Welco: [<Site>] <Pump> FAIL TO START at <time>. Reply STOP to opt out.
Welco: [<Site>] <Tank> level HIGH HIGH, <value> m at <time>. Reply STOP to opt out.
Welco: [<Site>] Wet well LOW LOW, pumps off at <time>. Reply STOP to opt out.
Welco: [<Site>] Chlorine residual LOW, <value> mg/L at <time>. Reply STOP to opt out.
Welco: [<Site>] Comm FAIL to RTU <name>, no data since <time>. Reply STOP to opt out.Try a template on your own phone
Paste one into your alarm email, point it at Welco and read the text in test mode first.
7-day free trial, 15 message creditsCard required for verificationNo charge for 7 daysEmail reminder before billing
IT monitoring alert templates
For server, network and service checks. Name the host the way your team says it out loud.
Welco: [<host>] Host DOWN, no ping reply at <time>. Reply STOP to opt out.
Welco: [<host>] <service> CRITICAL, <detail> at <time>. Reply STOP to opt out.
Welco: [<host>] Disk <drive> <percent>% full at <time>. Reply STOP to opt out.
Welco: [<site>] Internet link DOWN, on backup at <time>. Reply STOP to opt out.Batch job and backup templates
For overnight jobs, file transfers and backups. Text the failures and let successes stay in email.
Welco: [<system>] Job <name> FAILED at <time>. Reply STOP to opt out.
Welco: [<system>] <job> finished with errors at <time>. Reply STOP to opt out.
Welco: [<server>] Backup <name> did not run, last good <date>. Reply STOP to opt out.Building and HVAC alarm templates
For building automation points, from Delta Controls to Distech Controls systems. Add the room or floor so nobody has to look up a point name.
Welco: [<Building>] <AHU> supply air <value> C, off setpoint at <time>. Reply STOP to opt out.
Welco: [<Building>] Boiler <n> LOCKOUT at <time>. Reply STOP to opt out.
Welco: [<Building>] Door <name> FORCED OPEN at <time>. Reply STOP to opt out.
Welco: [<Building>] Door <name> HELD OPEN over <n> min at <time>. Reply STOP to opt out.Temperature and power templates
For freezers, cold rooms, server rooms, generators and UPS units. Give the reading and the limit.
Welco: [<Room>] Freezer <value> C, above <limit> C at <time>. Reply STOP to opt out.
Welco: [<Room>] Server room <value> C, high temp at <time>. Reply STOP to opt out.
Welco: [<Site>] Generator RUNNING, hydro power lost at <time>. Reply STOP to opt out.
Welco: [<Site>] UPS ON BATTERY, <n> min left at <time>. Reply STOP to opt out.Voicemail alert template
Most phone systems fix their own email wording, so this is what Welco keeps from it. The link plays the recording.
Welco: Voicemail on <line> from <caller>, <length>. Listen: <link> Reply STOP to opt out.Fill the placeholders from your system's own fields
Most monitoring tools have variables that drop live values into the alert email. Map each placeholder to the matching field, then put the result in the subject line.
Check the names against your own version before you save. SCADA and building systems use their own field names for area, tag, value and time.
<host> or <Site>
- Nagios macro
$HOSTNAME$- Zabbix macro
{HOST.NAME}- PRTG placeholder
%device
<service> or the fault
- Nagios macro
$SERVICEDESC$- Zabbix macro
{TRIGGER.NAME}- PRTG placeholder
%sensor
State, such as DOWN or CRITICAL
- Nagios macro
$HOSTSTATE$or$SERVICESTATE$- Zabbix macro
{TRIGGER.SEVERITY}- PRTG placeholder
%status
<value> or detail
- Nagios macro
$SERVICEOUTPUT$- Zabbix macro
{ITEM.LASTVALUE}- PRTG placeholder
%lastvalue
<time>
- Nagios macro
$SHORTDATETIME$- Zabbix macro
{EVENT.TIME}- PRTG placeholder
%datetime
Sources: Nagios Core 4 standard macros (read October 6, 2026); Zabbix manual: macros supported by location (read October 6, 2026); PRTG manual: placeholders for notifications (read October 6, 2026)
How to use a template
Find the alert field in your system
Look for the alarm email's subject or message setting. Many systems let you insert values like the site, tag, value and time.
Swap the placeholders
Replace each part in angle brackets with a field or a fixed name. Use short names your crew already uses on the radio.
Check the length
Count the middle part. If it runs past about 130 characters, cut words, not facts. The guide to short alert texts has more ways to trim.
Test before you rely on it
Turn on test mode, trigger the alarm and read the result in the Welco feed. Then switch test mode off.
Mistakes that make a template fail
A template can look fine on a desk screen and still read badly on a phone. Watch for these before you save it.
- Leaving a placeholder empty. Some systems send a blank where a field has no value, so the text reads
[ ] FAIL at 3:10 AM. - Pasting from a word processor. It swaps straight quotes for curly ones, and one curly quote shrinks the whole text to 70 characters.
- Putting the time zone and seconds in.
03:10:44 EDTadds nine characters the on-call person does not need. - Using one template for alarm and all-clear. Give the return to normal its own wording, or keep it in email.
- Writing the tag only in code. Pair
LT301with a word likeTank 1so a new hire can read it too.
Frequently asked questions
What should an alert message template include?
8 C, above 4 C, beats a word like HIGH when you have it. Anything else can stay in the email.Can I add instructions such as who to call to the template?
Do the templates work if my alerts are in French?
Should the all-clear message use the same template?
[Tank 1] Level back to NORMAL at 6:52 AM. Most teams keep these in email so phones only buzz for problems. If you do text them, a rule on words like NORMAL can send them to one person only.How do I know a template fits in one text?
Welco: and the STOP line take about 30 more. Then send it once in test mode. The Welco feed shows the finished text and how many message credits it would use.Put your first template on the on-call phone
Copy a line, paste it into your alarm email and send it to Welco.