Ignition SMS alarm notification through the email you already send
Ignition SMS alarm notification can run on the alarm email your pipeline already sends: add one roster contact with your Welco address. When a tag goes into alarm at 1 a.m., the operator on call reads the area, the alarm and the value in one text. No SMS module, no cellular modem and no messaging account to fund.
7-day free trial, 15 message creditsCard required for verificationNo charge for 7 daysEmail reminder before billing
- No SMS or Voice module
- One roster contact to add
- No per-user fees
Works by email with
- Ignition
Published:
A Ignition HMI screen with a Filters process mimic and an alarm summary: the row Filters/Train2/GenAlarm, General Alarm, appears ActiveUnacked with priority High above two acknowledged alarms. The email reaches Welco and the phone shows: “Welco: [Train 2] Filter general alarm ACTIVE at 1:37 AM. Reply STOP to opt out.”
What changes when Ignition alarms become texts
The operator reads it on the lock screen
The text drops the display path and the source string. What is left is the area, the alarm, the value and the time.
Your pipelines stay in charge
Rosters, priorities and the alarm journal stay in Ignition. Welco only chooses which phone gets each email, by time of day.
The gateway stays behind the firewall
Welco never connects to your gateway. It only receives the mail your email profile sends out, so no inbound port is opened.
A radio drop won't flood the phone
When an ice storm takes out a radio repeater and forty remote tags trip, flood control holds the texts to a few. The alarm status table keeps the full list.
What you need for Ignition SMS alarm notification
Ignition (by Inductive Automation) sends alarm email through its Alarm Notification module and an email profile. If your gateway emails alarms today, you are most of the way to SCADA alarm notification by SMS.
- An email notification profile that can reach a mail server, such as the municipality's mail relay or Microsoft 365.
- An alarm pipeline with a notification block, and alarms on your tags that point to that pipeline.
- A Welco account with your business verified. Start free if you don't have one yet.
- Operators who join from a Welco invite on their own cellphone. Each replies YES to a first text before any alarm reaches them.
Set up Ignition alarm texts in 6 steps
Menu names below match the Ignition 8.1 gateway and Designer. Whoever maintains your gateway can do this in about 20 minutes, most of it testing. For another SCADA package, use the SCADA alarm text setup guide.
Approve the gateway's From address in Welco
Find the From address your email profile uses, for example
ignition@gateway.example.org. Add it to the senders allowed to trigger texts. Mail from any other address is turned away.Check the email notification profile
On the gateway, open Config, then Alarming, then Notification. Make sure an Email Notification profile exists and its mail server test works.
Create a user for the Welco address
In your user source, add a user such as
welco-oncall. Under its contact info, add an email entry and paste your Welco address.Put that user on an on-call roster
Open Alarming, then On-Call Rosters, and add the new user to the roster your pipeline uses. You can also build a roster just for texts.
Point the pipeline at the roster
In the Designer, open Alarm Pipelines and select the notification block. Choose the email profile on its Notification tab and the roster on its Contacts tab, then save the project.
- Keep the message short. Site, point, state and time are enough for a text.
- Check that each tag alarm's Active Pipeline is set to this pipeline.
Trip a test alarm
Force a test tag into alarm and watch the Welco feed. Turn on Welco's no-send test mode first if you want to see the result without sending a text.
Your Ignition pipeline can text tonight
Verify your business, add a roster user with your Welco address, and trip a test alarm.
7-day free trial, 15 message creditsCard required for verificationNo charge for 7 daysEmail reminder before billing
An Ignition reservoir alarm before and after
Ignition's default email wording repeats the display path and the full alarm source. Welco keeps the reservoir, the state, the level and the time.
Alert email from ignition@gateway.example.org, subject “Alarm Notification: High Level”. Welco trims it to one text of 86 characters: “Welco: [East Reservoir] High Level ACTIVE, 9.6 m at 10:15 PM. Reply STOP to opt out.”
Text received: Welco: [East Reservoir] High Level ACTIVE, 9.6 m at 10:15 PM. Reply STOP to opt out.
Characters246861 credit
You control the trim with a rule. See how trimming to one text keeps long alarm emails to the part an operator needs. Municipal systems running Ignition can see more in water and wastewater alarm texts.
Tips for Ignition alarm texts
A few choices make the difference between texts people trust and texts people mute.
Night alarms to the standby phone
Rosters decide who gets the email. Welco on-call routing then picks the phone by time of day, so nobody edits a roster at every shift change.
Lead operator and backup together
One Welco address can reach two or three phones at once. Each phone gets one copy, even if the gateway sends the email twice.
Bundle a comm-loss storm
Turn on consolidation in the notification block so many remote tags arrive as fewer emails. Welco flood limits catch whatever still gets through.
Keep Cleared out of texts
If the pipeline also emails clears, an alert rule drops any email that says Cleared. A text then always means a live alarm.
If an Ignition alarm doesn't become a text
Work through these in order. The first two cover most cases.
0 of 4 done
Frequently asked questions
Do I need the Ignition SMS or Twilio Notification module?
Does Welco connect to the Ignition gateway or our control network?
Can an operator acknowledge an Ignition alarm by replying to the text?
Can I keep the Voice module or our dialer for callouts?
Do operators need Perspective or an Ignition app to read the alarm?
Can I use system.net.sendEmail instead of a pipeline?
system.net.sendEmail and an SMTP server. Put your Welco address in the recipient list instead of a carrier address like number@txt.bell.ca, which Bell retired on December 31, 2025. The Welco steps are the same: approve the sender, invite the operators, and test.Will cleared and acknowledged alarms also turn into texts?
What did the Ignition notification modules cost?
Turn your Ignition pipeline email into a text
Add one roster user with your Welco address and the standby phone hears about the next alarm.
7-day free trial, 15 message creditsCard required for verificationNo charge for 7 daysEmail reminder before billing