VTScada SMS alarm texts from a VTScada email notification
VTScada SMS alarm texts can come from a VTScada email contact instead of a modem: make that contact your Welco address. When a well pump faults at 3:44 a.m., the standby phone names the well, the fault and that nobody has acknowledged it yet. Every alarm on that roster arrives as a short text.
7-day free trial, 15 message creditsCard required for verificationNo charge for 7 daysEmail reminder before billing
- No modem at the SCADA server
- One email contact to add
- No per-user fees
Setup guide for
- VTScada
Published:
A VTScada HMI screen with a Wells process mimic and an alarm summary: the row Well 5 Pump Fault, Pump Fault, appears Active, Unack with priority Critical above two acknowledged alarms. The email reaches Welco and the phone shows: “Welco: [Well 5] Pump FAULT, critical, unacked at 3:44 AM. Reply STOP to opt out.”
What VTScada operators get from email texts
Site, alarm and reading in one line
Each text names the well or reservoir, what tripped, the value and whether it is still unacked.
Nights reach whoever has standby
VTScada keeps its roster. Welco then sends night texts to the standby phone and daytime texts to the crew.
No modem or phone line to test
The email part of VTScada notification does the work. There is no dial-out hardware at the SCADA server to keep alive.
Nothing new on the SCADA network
Welco receives the mail after your relay sends it. No agent runs on the VTScada server and no inbound connection is opened.
VTScada notification and where Welco comes in
VTScada is SCADA software (the system that watches and runs a plant or a set of remote sites). Its built-in alarm notification can use phone, SMS, email and pager, with rosters of up to 30 contacts, as listed on vtscada.com, October 2026.
Any system that can send an email works with Welco's SCADA alarm notification service. Here's how to set up VTScada. You use the email part of its notification, and Welco turns each email into a text. Before you begin, have these ready.
- A mail server VTScada can send through, such as the municipality's mail relay or Microsoft 365.
- A Welco account with your municipality or business verified. Start free to open one.
- Your operators, each joined from a Welco invite on their own cellphone. Each gets one text first and replies YES.
Set up VTScada SMS alarm texts in 5 steps
VTScada versions lay out their settings differently. Look for the email or SMTP notification settings in VTScada, or ask your integrator where they are. Plan on half an hour, most of it testing.
Set up outgoing email in VTScada
Find the email or SMTP settings and enter your mail server. Send a test email to yourself to prove it works before you add Welco.
Approve the sending address in Welco
Note the From address VTScada uses. In Welco, add it to your approved senders. Mail from other addresses is refused.
Add a contact with your Welco address
In VTScada's alarm notification setup, add a contact whose email is your Welco address. Put it on the roster that should get alarms by text.
Choose which alarms send email
Send email for the alarm priorities that need a person, such as Critical and High. Leave lower priorities on the alarm screen.
Test with a real alarm
Trigger a safe test alarm and check the text and the Welco feed. Welco can log a test without sending a text.
Turn a VTScada alarm email into a text
Add one email contact in VTScada and verify your business with Welco.
7-day free trial, 15 message creditsCard required for verificationNo charge for 7 daysEmail reminder before billing
Sample reservoir alarm, before and after
Alarm emails tend to repeat the area, the status and the server name. The text keeps the site, the reading and the time.
Alert email from vtscada@water.example.org, subject “Alarm: Hill Reservoir Level Low”. Welco trims it to one text of 77 characters: “Welco: [Hill Reservoir] Level LOW, 3.4 m at 9:05 PM. Reply STOP to opt out.”
Text received: Welco: [Hill Reservoir] Level LOW, 3.4 m at 9:05 PM. Reply STOP to opt out.
Characters235771 credit
How much to keep is up to you. See one-text alerts, and water and wastewater alarm texts for the alarms municipal systems route most.
Tips once VTScada is texting
A few Welco settings keep texts useful as you add more sites.
Who is on call tonight
VTScada's roster decides who gets email. Welco on-call routing can then send night texts to one phone and day texts to the crew.
Several people, one alarm
One Welco address can text the operator and the public works superintendent at once. Each phone gets a single copy.
Drop the all-clear emails
If VTScada emails when an alarm returns to normal, an alert rule can keep those in email. A text then always means something still needs a look.
Radio fade and winter outages
When a radio path fades or an ice storm cuts power, many remote sites alarm together, a classic SCADA alarm flood. Welco caps texts during a flood, so the phone stays usable.
Fixing a missing VTScada text
Start at VTScada and move toward the phone.
0 of 4 done
Frequently asked questions
VTScada has SMS built in. Why would I use email and Welco?
Do I need to install anything on the VTScada server?
Can I send alarms from different VTScada sites to different crews?
Does replying to a VTScada text acknowledge the alarm?
Can VTScada still call operators while Welco sends the texts?
Will the VTScada alarm emails we get today still arrive?
What will VTScada alarm texts cost?
Send your VTScada alarm email to a phone
Add one email contact in VTScada and the next alarm can arrive as a text.
7-day free trial, 15 message creditsCard required for verificationNo charge for 7 daysEmail reminder before billing