PLC alarm SMS for Canadian plants, no modem in the panel
PLC alarm SMS doesn't need a modem in the panel. Once your HMI, SCADA, a gateway or a plant app emails the fault, Welco turns it into one short text. A lathe stops on the night shift with a broken tool, and the on-call tech reads the machine and the fault in plain words.
7-day free trial, 15 message creditsCard required for verificationNo charge for 7 daysEmail reminder before billing
- No SIM or modem in the panel
- PLC logic can stay as it is
- No per-user fees
Works by email with
- PLC alarms
- Ignition
- GE iFIX
Setup guide for
- FactoryTalk
A PLC chassis with a power supply, CPU and four I/O modules: input I:3/5 from pressure switch LT-11 chatters, the channel faults, the slot 3 FAULT LED blinks and the CPU passes the alarm to PLANT. The email reaches Welco and the phone shows: “Welco: [LT-11] STOPPED, load monitor tool broken at 5:48 AM. Reply STOP to opt out.”
What PLC alarm texts give the on-call tech
The machine and the fault, in words
The text says LT-11 stopped, tool broken. Bit names and part counts stay behind in the email.
Only the tech who can fix it
A rule reads the machine or cell name and texts that area's tech instead of the whole plant.
No SIM card in the cabinet
Texts go out from Welco's alert numbers, so no panel needs its own cellular plan.
A chattering sensor stays quiet
If a loose prox sets and clears a bit all night, flood control caps the texts until you fix the logic.
How a PLC fault turns into an email
A programmable logic controller (PLC) is the rugged industrial computer that runs a machine, a pump or a line. It knows the moment a motor trips. Most PLCs can't send email by themselves, so something beside them does it.
- The HMI or SCADA. The screen or server reading the PLC sends an alarm email, as with FactoryTalk line alarms. It's the most common route. See the SCADA systems Welco covers.
- The PLC itself. Some controllers and panel HMIs have an email function that logic can call when a bit turns on.
- A gateway or RTU. A cellular or network box reads PLC tags and sends an email when one changes.
- A plant app or database job. A small service watches tags or a SQL table and emails when a row reads ALARM.
Set up PLC alarm SMS in 4 steps
These steps assume one of the email routes above already works, or your controls team can add one. The full SCADA setup guide goes into more detail.
Choose the alarms worth a text
Pick faults that stop production or risk damage: motor overload, e-stop, low oil, high temperature, loss of air. Leave operator prompts and counters on the HMI.
Approve the sender and invite your techs
In Welco, add the address that sends the alarm email to the senders Welco trusts. Invite each tech by email. Each tech joins from their own cellphone and confirms with a YES reply.
Send the alarm email to your Welco address
In the HMI, gateway or app, add your Welco address as a recipient. Put the machine name and the fault first in the message.
Trip a test fault on an idle machine
Force a harmless alarm bit and check the text. Welco test mode shows the result in the feed without sending anything.
Get your next machine fault on a phone
Send the PLC alarm email to Welco and invite the tech on call.
7-day free trial, 15 message creditsCard required for verificationNo charge for 7 daysEmail reminder before billing
A stamping press on the night shift
An auto parts plant in southern Ontario. One fault goes to the one person who can fix it.
The plant app emails the press fault
PRESS-06 ALARM Status RUNNING/WARN ALARM_H; Hydraulic oil temp 64 CA rule picks the millwright, not the electrician
The machine name matches the press cell, and hydraulic faults go to the on-call millwright.
The millwright sees the press and the temperature
Welco: [Press 6] Hydraulic oil temp HIGH, 64 C at 1:40 AM. Reply STOP to opt out.A short reply for the shift lead
Oil cooler fan likely. On site in 25 minThe maintenance mailbox gets the note
Welco emails each reply to the alarm's sender. Forward a no-reply sender to the maintenance inbox.
Reply from the on-call millwright: Oil cooler fan likely. On site in 25 minThe fault is reset at the HMI
The press alarm is cleared at the machine, as usual. Replying to a text never resets anything.
Times are an example. Text delivery depends on mobile networks.
More PLC alarm texts
Masked examples of controller faults that factories, mills and packaging lines send to a phone. A one-text trim rule shapes each one.
- Dry kiln: Welco: [Dry Kiln 2] Circulation fan 3 TRIPPED at 12:36 AM. Reply STOP to opt out.
- Air: Welco: [Compressor Room] Header pressure LOW, 540 kPa at 4:55 AM. Reply STOP to opt out.
- Robot cell: Welco: [Weld Cell 5] Safety gate OPEN, cell stopped at 3:19 AM. Reply STOP to opt out.
Reach the right tech, not the whole plant
PLC alarms are precise. Use that to text only the person who can fix the fault.
By machine or cell
An alert rule matches the machine name and sends the text to that cell's tech.
By shift
On-call routing sends night-shift faults to the on-call tech and day faults to the area lead.
When a fault chatters
Add a delay or a latch in the logic first, so one fault sends one email. Flood limits protect the phone meanwhile.
Frequently asked questions
Do I still need a cellular modem or SIM card on the PLC?
Does Welco connect to our PLCs or the controls network?
Which PLC alarms are worth a text?
Can a tech reset or acknowledge a fault by replying to the text?
Can one email carry several alarm bits?
What does it cost to text PLC alarms?
Text controller faults to the tech who can fix them
Send your PLC alarm email to Welco and test it on an idle machine before the next night shift.
7-day free trial, 15 message creditsCard required for verificationNo charge for 7 daysEmail reminder before billing