PLC alarm SMS without a modem in the control panel
PLC alarm SMS works without a modem in the panel. Once your HMI, SCADA, a gateway or a plant app emails the fault, Welco turns it into one short text. When a turning machine stops on third shift with a broken tool, the tech on call reads the machine and the fault in plain words. No SIM card in the cabinet.
7-day free trial, 15 message creditsCard required for verificationNo charge for 7 daysEmail reminder before billing
- No SIM or modem in the panel
- No change to PLC logic needed
- No per-user fees
Works by email with
- PLC alarms
- Ignition
- GE iFIX
Setup guide for
- FactoryTalk
A PLC chassis with a power supply, CPU and four I/O modules: input I:3/5 from pressure switch LT-07 chatters, the channel faults, the slot 3 FAULT LED blinks and the CPU passes the alarm to PLANT. The email reaches Welco and the phone shows: “Welco: [LT-07] STOPPED, load monitor tool broken at 6:12 AM. Reply STOP to opt out.”
What the tech on call gets from PLC alarm texts
The machine and the fault in words
The text says LT-07 stopped, tool broken. Bit names and part counts stay in the email.
Only the tech who can fix it
A rule reads the machine or cell name and texts that area's tech, not the whole plant.
No SIM card in the cabinet
Texts come from Welco's alert numbers, so no panel needs a cellular plan of its own.
A chattering sensor stays quiet
When a loose sensor sets and clears a bit all night, flood control caps the texts while you fix the logic.
How a PLC fault becomes an email
A programmable logic controller (PLC) is the small industrial computer that runs a machine, a pump or a line. It knows the moment a motor trips. Most PLCs don't send email on their own, so something next to them does.
- The HMI or SCADA. The screen or server that reads the PLC sends an alarm email, as with FactoryTalk line alarms. This is the most common path. See the SCADA systems Welco covers.
- The PLC itself. Some controllers and panel HMIs have an email function you can call from logic when a bit turns on.
- A gateway or RTU. A cellular or network box reads PLC tags and emails on a change.
- A plant app or database job. A small service watches tags or a SQL table and emails when a row says ALARM.
Set up PLC alarm SMS in 4 steps
These steps assume one of the email paths above is working, or can be added by your controls team. The full SCADA setup guide goes deeper.
Pick the alarms that deserve a text
Choose faults that stop production or risk damage: motor overload, e-stop, low oil, high temperature, loss of air. Leave operator prompts and counters on the HMI.
Approve the sender and invite your techs
In Welco, add the address that sends the alarm email to the senders Welco trusts. Invite each tech by email. They join with their own mobile and reply YES.
Point the alarm email at your Welco address
In the HMI, gateway or app, add your Welco address as a recipient. Put the machine name and the fault at the start of the message.
Trip a test fault on an idle machine
Force a harmless alarm bit and check the text. Welco test mode shows the result in the feed without sending.
Send your next machine fault to a phone
Point the PLC alarm email at Welco and invite the tech on call.
7-day free trial, 15 message creditsCard required for verificationNo charge for 7 daysEmail reminder before billing
A hot press on third shift
One fault, routed to the one person who can fix it.
The plant app emails the press fault
PRESS-04 ALARM Status RUNNING/WARN ALARM_H; Hydraulic oil temp 62 CA rule picks the mechanic, not the electrician
The machine name matches the press cell, and hydraulic faults go to the on-call mechanic.
The mechanic sees the press and the temperature
Welco: [Press 4] Hydraulic oil temp HIGH, 62 C at 2:30 AM. Reply STOP to opt out.A quick reply to the shift lead
Checking the oil cooler fan. 20 minThe maintenance mailbox gets the note
Welco emails replies to the alarm's sender. Forward a no-reply sender to the maintenance inbox.
Reply from the on-call mechanic: Checking the oil cooler fan. 20 minThe fault is reset at the HMI
The press alarm is cleared at the machine, as always. A text reply never resets anything.
Times are an example. Text delivery depends on mobile networks.
Other PLC alarm texts
Masked examples of controller faults that factories and packaging lines send to a phone. A one-text trim rule shapes each one.
- Extruder: Welco: [Extruder 2] Barrel zone 3 heater FAULT at 12:52 AM. Reply STOP to opt out.
- Air: Welco: [Compressor Room] Header pressure LOW, 78 psi at 5:17 AM. Reply STOP to opt out.
- Robot cell: Welco: [Robot Cell 3] Safety gate OPEN, cell stopped at 1:44 AM. Reply STOP to opt out.
Getting the right tech, not the whole plant
PLC alarms are specific. Use that to text only the person who can fix it.
By machine or cell
An alert rule can match the machine name and send the text to that cell's tech.
By shift
On-call routing sends third-shift faults to the on-call tech and day faults to the area lead.
When a fault chatters
Add a delay or latch in the logic first, so one fault sends one email. Flood limits protect the phone in the meantime.
Frequently asked questions
Do I still need a GSM modem or SIM card on the PLC?
Does Welco connect to our PLCs or the controls network?
Which PLC alarms should I text?
Can a tech reset or acknowledge the fault by replying?
Can one email include several alarm bits?
What does it cost to text PLC alarms?
Send controller faults to the tech who can fix them
Point your PLC alarm email at Welco and test it on an idle machine.