Oil and gas SCADA alarm texts for pumpers and field crews
A high tank on a pad or a compressor down at the station should reach the pumper on call before oil hits the berm. Welco reads the alarm email your SCADA host already sends and texts the site, the equipment and the reading. You add one recipient on the host, and your radios and field network stay untouched.
7-day free trial, 15 message creditsCard required for verificationNo charge for 7 daysEmail reminder before billing
- Works from your SCADA host's email
- Nothing on radios or field network
- No per-pumper fees
Works by email with
- Ignition
- Tank & well levels
- WIN-911
Setup guide for
- FactoryTalk
A pump station schematic: Tank 2 level rises above its 13.6 ft high alarm setpoint to 14.2 ft and the alarm turns on. The email reaches Welco and the phone shows: “Welco: [Pad 7 Tank Battery] Oil tank 2 level HIGH, 14.2 ft at 11:06 PM. Reply STOP to opt out.”
What a field office gets from Welco
The pumper or mechanic on call gets tank, compressor and pressure alarms by text, with the site and the reading. They come from your SCADA host's alarm email.
The pumper reads the gauge before driving
Tank level alarm texts carry the feet of fluid, so a 40-minute drive starts only when the number calls for it.
Compressors go to the mechanic
A unit shutdown texts the mechanic on call, and a high-high tank can add the field supervisor through several phones per alert.
A power drop stays a few texts
When a line goes down, power loss alarms fire from many pads together. Flood control caps the burst on each phone.
Only your host can text crews
With approved senders, mail from anything except your SCADA host or a trusted contract operator is refused.
A water tank filling up on a Sunday night
The pumpers have gone home, and one lease operator covers the whole field tonight. Here is one tank battery alarm, start to finish.
Routes hand off to the night operator
At 6 PM, on-call routing stops texting each route's pumper and sends tank and well alarms to the lease operator.
The SCADA host emails a level alarm
--- ALARM --- HIGH --- PAD12_TB.WTR_TK3.LVL Water tank 3 level 15.1 FT Area: South FieldThe lease operator sees the tank and the level
Welco: [Pad 12 Battery] Water tank 3 HIGH, 15.1 ft of 16 ft at 11:52 PM. Reply STOP to opt out.The operator answers from the lease road
Shutting in Pad 12 wells, need a water haul at 6The reply reaches the field office mailbox
Welco sends text replies by email to the alarm's sender, so the foreman reads the plan before the first call.
Reply from the lease operator's phone: Shutting in Pad 12 wells, need a water haul at 6The foreman books the water haul
The haul gets scheduled from the reply, and the delivery report confirms the text reached the operator's phone.
Times are only an example. Mobile networks set how fast a text arrives. Replying leaves the HIGH alarm standing on the SCADA host.
How to set up field alarm texts from the office
Whoever looks after the SCADA host can do it in an afternoon. The host only needs one more email recipient on its alarm list.
Sign up and verify the company
Tell us about the operation and the alarms you'll send. Each business is checked first, so the alert number carries field alarms only.
Invite pumpers and mechanics
Each person types their own mobile on the invite and confirms by text. Contract pumpers can join the same way.
Point the host at Welco
Add your Welco address to the alarm email and approve the host's sender. Run real alarms in test mode while the old notifier keeps working.
Text the next high tank alarm to the pumper
Sign up, verify your company and point your SCADA's alarm email at Welco.
7-day free trial, 15 message creditsCard required for verificationNo charge for 7 daysEmail reminder before billing
Which field SCADA systems can send alarm texts?
Most field data reaches a SCADA host in the office over radio, cell or satellite, and that host sends the email. Guides cover WIN-911 alarm emails, Ignition SMS alarms, VTScada alarm notification and AVEVA InTouch at gas plants. Compressor stations can use FactoryTalk alarm text messages or PLC alarms by text.
- IgnitionGateway alarm email
- FactoryTalkCompressor station controls
- WIN-911Pass its emails on as texts
- VTScadaField SCADA host roster
- AVEVA InTouchGas plant HMIs
- PLC alarmsPump and compressor controllers
- Tank & well levelsTank batteries and SWD sites
- Data loggersRemote pressure and flow points
- Generator & powerPower loss at stations
Lease and station alarms field crews act on
These are masked examples. Manufacturing plants and electric utility substations watch many of the same pressures and power feeds, so compare alarm texts in other industries.
- Gathering line: Welco: [GL-4 Meter Run] Flow 0 MCF/D, was 1,240 at 1:36 AM. Reply STOP to opt out.
- Compressor station: Welco: [CS-5] Unit 1 SHUTDOWN on high vibration at 3:58 AM. Reply STOP to opt out.
- Pad: Welco: [Pad 3] Pumping unit 3H STOPPED, motor fault at 5:12 AM. Reply STOP to opt out.
Which oil and gas alarms should text the pumper on call?
Text the alarms that end in a spill, a shut-in or lost sales before the morning route. Small pressure swings and trend data can wait in email.
Worth a night text
- An oil or water tank HIGH or HIGH-HIGH at a battery.
- An SWD injection pump failure, or injection pressure over its limit.
- A compressor unit shutdown.
- Gathering line pressure above its limit, or flow dropping to zero.
- A pumping unit that stops.
- Power lost at a pad or a station.
Leave in email
Runtime reports, daily production totals, plunger cycle counts and alarms from wells already shut in. The foreman reviews those in daylight.
Cover the dead spots on the lease
Lease roads lose signal, and a text waits until the phone finds one. Send HIGH-HIGH tank alarms to two people who work opposite ends of the field. Use alarm wording a pumper can read fast.
A disposal well alarm, from SCADA email to text
Field SCADA emails often wrap the alarm in dashes and long point names. Welco keeps the site, the equipment and the state.
Alert email from scada@field.example.com, subject “New Alarm from SWD-2”. Welco trims it to one text of 83 characters: “Welco: [SWD-2] Injection pump 1 FAIL, stopped at 12:51 AM. Reply STOP to opt out.”
Text received: Welco: [SWD-2] Injection pump 1 FAIL, stopped at 12:51 AM. Reply STOP to opt out.
Characters173831 credit
An alert rule can send HIGH-HIGH alarms to the phone and keep lower priorities in email.
Night alarms in the oil patch, then and now
The old way
- Every pumper's phone buzzes for every pad on the lease.
- The notifier says ALARM, and the operator calls the office to learn the level.
- A full tank turns up on the morning route.
- Alarm texts ride on a carrier gateway address that is being switched off.
With Welco
- Each route to its own pumper by day, the lease operator by night.
- The tank, the level and the limit on the lock screen.
- Compressor shutdowns text the mechanic, not the whole crew.
- The night's replies wait in the field office mailbox.
Frequently asked questions
Our SCADA host is in the field office. Can it send the alarms?
What does the pumper see, and do they need an app?
Do we still need WIN-911 if we use Welco?
What happens if the on-call pumper is out of cell range?
Does Welco need access to our SCADA network or radios?
What does it cost, and do the office alarm emails change?
Have the next high tank alarm reach the pumper before it spills
Point your SCADA's alarm email at Welco and add your field phones.
7-day free trial, 15 message creditsCard required for verificationNo charge for 7 daysEmail reminder before billing