GE iFIX alarm SMS: tag alarms on the on-call phone
GE iFIX alarm SMS reaches the operator on call once you add your Welco address to the alarm email iFIX already sends. A boost pump fails to start at 3 a.m., and one text shows the group, the tag description, the value and the time. Your tag database and pictures stay exactly as they are.
7-day free trial, 15 message creditsCard required for verificationNo charge for 7 daysEmail reminder before billing
- No change to tags or pictures
- No modem at the SCADA node
- No per-user fees
Works by email with
- GE iFIX
Published:
A GE iFIX HMI screen with a WTP process mimic and an alarm summary: the row BP3_FTS, BOOST PUMP 3 FAIL TO START ALARM, appears ALM UNACK with priority HIGH above two acknowledged alarms. The email reaches Welco and the phone shows: “Welco: [WTP] Boost Pump 3 fail to start, ALM at 3:21 AM. Reply STOP to opt out.”
iFIX alarm callouts before and after Welco
The iFIX alarm email today
- Tag alarms land in a shared mailbox that nobody opens after the day shift.
- Texts sent to carrier addresses such as
txt.bell.caquietly stopped arriving. - Node, tag name, priority and event code come before the part that matters.
- A restart of the SCADA node sends a long burst of mail at once.
With your Welco address added
- The on-call operator gets the group, the description and the value.
- Alerts-only numbers carry the text instead of a carrier gateway.
- A trim rule keeps each tag alarm to one short line.
- Flood limits turn a restart burst into a handful of texts.
Before you set up iFIX alarm texts
GE iFIX is the HMI and SCADA software (the screens and the system that watch a plant) many municipal water plants and manufacturing plants run. Sites send iFIX alarm email in different ways, and a SCADA alarm text service like Welco only needs that email. It may come from a script on the SCADA node, an alarm notifier, or a reporting tool your integrator set up.
You need three things before you start.
- An iFIX alarm email that someone receives today, even if it only goes to a shared mailbox.
- A verified Welco account. Start free and verify your municipality or company.
- The operators who take standby, ready to join from a Welco invite on their own cellphone and confirm with YES.
Set up iFIX alarm SMS in 5 steps
You won't touch iFIX tags or pictures. The change is in whatever sends the alarm email, and your SCADA tech or integrator can make it in one site visit.
Find the tool that sends iFIX alarm email
Look at a recent alarm email. The From address and the wording tell you which script or notifier sent it. Your integrator's notes are the next place to check.
Approve that From address in Welco
Add the sender, such as
ifix-alarms@plant.example.org, to your list of approved alarm senders. Welco refuses email from any address you haven't approved.Add your Welco address as a recipient
In the script or notifier, add your Welco address next to the existing recipients. If it lists carrier addresses like
4165550123@txt.bell.ca, swap those out. Bell retired its Text via Email service on December 31, 2025.Send only the alarm groups you want texted
If the tool can filter by alarm area or priority, keep texts to HIGH and CRITICAL. Otherwise, filter in Welco with an alarm rule that matches the group or the words in the description.
Force one tag into alarm
Pick a safe test tag and put it in alarm. Check the Welco feed for the email and the text. Use test mode for a silent trial if you'd rather not send a real text yet.
Get iFIX tag alarms on your phone this week
Add one recipient to your iFIX alarm email. Your tags and pictures stay as they are.
7-day free trial, 15 message creditsCard required for verificationNo charge for 7 daysEmail reminder before billing
A chlorine residual alarm from iFIX
Analyzer alarms carry a value that matters, and a low residual leaving the plant is one an operator acts on right away. Welco keeps the value and drops the node name, the event code and the priority line.
Alert email from ifix-alarms@plant.example.org, subject “iFIX Alarm: WTP CL2_RES_LO”. Welco trims it to one text of 96 characters: “Welco: [WTP] Treated water chlorine residual LOW, 0.18 mg/L at 9:46 PM. Reply STOP to opt out.”
Text received: Welco: [WTP] Treated water chlorine residual LOW, 0.18 mg/L at 9:46 PM. Reply STOP to opt out.
Characters191961 credit
Want shorter still? Our guide to trimming alarm wording shows which words to cut.
Make iFIX texts worth waking up for
Operators trust texts that only show up when they matter. These settings help.
Night alarms to one phone
With on-call routing, alarms after the day shift go to the standby operator. Daytime alarms can go to the plant lead instead.
A backup phone for the big ones
Send CRITICAL alarms to the standby operator and the chief operator together. Each phone gets the text once.
Leave the all-clear in email
Some iFIX setups email both the alarm and its return to normal. A rule can drop any email whose event line shows OK, so a text always means a live alarm.
Quiet the burst after a restart
When the SCADA node restarts after a winter power outage, iFIX can report a long list of alarms at once. Flood control holds texts to a few, so the phone stays usable.
When an iFIX alarm doesn't text
Start at the plant end and work toward the phone.
0 of 4 done
Frequently asked questions
Does iFIX need an add-on to send alarm texts through Welco?
Will Welco change my iFIX project or touch the plant network?
Can each plant area text a different operator?
If an operator replies to an iFIX text, is the alarm acknowledged?
Can the iFIX alarm email still go to our shared inbox too?
Can we keep our autodialer while iFIX alarms go out as texts?
What does it cost to text iFIX alarms?
Put your iFIX tag alarms on the standby phone
One extra recipient on the alarm email is all iFIX needs.
7-day free trial, 15 message creditsCard required for verificationNo charge for 7 daysEmail reminder before billing