QEI SCADA alarm text for breaker trips and substation alarms
A QEI SCADA alarm text puts the substation, breaker and time on the on-call powerline technician's phone, even when the control room is empty. Setup is one more address on the master station's alarm email list. A feeder breaker that opens at 2:51 a.m. then reaches the crew as one line, and the master station keeps working unchanged.
7-day free trial, 15 message creditsCard required for verificationNo charge for 7 daysEmail reminder before billing
- Nothing added to the master station
- No dialer or phone line
- No per-user fees
Works by email with
- QEI
Published:
A substation one-line for Sub 7: breaker 52-3 on feeder 3 opens, the feeder loses power and the RTU reports it to the master station. The email reaches Welco and the phone shows: “Welco: [Sub 7] Feeder 3 breaker OPENED at 2:51 AM. Reply STOP to opt out.”
What a small hydro utility crew gets from QEI texts
The trip reaches whoever is home on call
No control room staffed at night? The text names the substation, the feeder and the breaker state.
A storm stays readable
When freezing rain or wet snow opens breakers across many substations, flood limits cap the texts per phone. The console keeps every event.
Priority 1 reaches two phones
Send breaker trips to the on-call powerline technician and the operations supervisor together. Lower priorities can go to one phone.
The SCADA network stays separate
Welco reads outgoing alarm mail only. It never reaches the master station, an RTU or the console.
Who this setup is for
A QEI system is SCADA (the system that watches and controls remote sites) for a utility. Its master station collects status from RTUs, the field units in each substation.
This page is for small electric and public utility teams, such as a town's hydro utility, often with one powerline technician on call from home. Welco sends SCADA alarms as texts to that phone. You need three things.
- Alarm email from the master station, or from a reporting or notifier tool that reads its alarm list. Ask your QEI support contact if you aren't sure it's turned on.
- A Welco account with your utility verified. Start free to begin.
- Each crew member on the call list, joined from a Welco invite on their own cellphone. Every phone confirms with YES before alarms go to it.
Set up QEI SCADA alarm texts in 5 steps
Your master station's screens depend on its version, so look for the alarm email or SMTP settings in the system you have. Plan for a short window with your SCADA tech or QEI support contact.
Find the alarm email settings
Look for where the master station, or its notifier, lists email recipients for alarms. That is where your Welco address goes.
Approve the master station as a sender
Copy the From address on a recent alarm email. Add it to Welco's approved senders, so only your SCADA can text your crew.
Add your Welco address
Add your Welco address next to the existing recipients. Keep the operations mailbox on the list so the full email is still on file.
Pick which points send email
If you can, send email only for breaker status, relay trips and loss of station service. Leave analog warnings for the console.
Test on a safe point
Toggle a test point or a spare breaker status during a planned window. Check the text and the Welco feed before you rely on it. Welco test mode lets you check the feed first with no text sent.
Get the next breaker trip on the on-call phone
Add your Welco address to the master station's alarm email. Your SCADA stays as it is.
7-day free trial, 15 message creditsCard required for verificationNo charge for 7 daysEmail reminder before billing
An early wet snowstorm hits the service area
Heavy snow on trees that still have their leaves brings down lines fast. Storms are when small utilities need texts most, and when phones are most at risk of a flood. The guide to keeping an alarm flood off the phone covers the master station side.
The master station emails the first trip
SUB 4 2026-10-06 23:02:11.540 BREAKER STATUS OPENEDThe on-call powerline technician sees it first
Welco: [Sub 4] Feeder 2 breaker OPENED at 11:02 PM. Reply STOP to opt out.Sub 9 and Sub 11 trip within two minutes
SUB 9 2026-10-06 23:04:37.112 BREAKER STATUS OPENEDFlood limits hold back the rest
Each phone gets a few texts that show several stations are out. The console still lists every status change.
The technician answers from the bucket truck
Rolling to Sub 4 first, roads are slickThe operations supervisor reads the reply in email
Welco emails replies to the alarm's sender. Send master station mail through a mailbox the supervisor watches.
Reply from the on-call powerline technician: Rolling to Sub 4 first, roads are slick
Times are an example. Text delivery depends on mobile networks and coverage.
A breaker closing back in, as a text
After a recloser or an operator closes a breaker, the master station sends a matching status email. Some crews want that text too, so they know power is back.
Alert email from scada-master@utility.example.org, subject “SCADA ALARM: SUB 12 BREAKER STATUS”. Welco trims it to one text of 76 characters: “Welco: [Sub 12] Feeder 1 breaker CLOSED at 3:06 AM. Reply STOP to opt out.”
Text received: Welco: [Sub 12] Feeder 1 breaker CLOSED at 3:06 AM. Reply STOP to opt out.
Characters162761 credit
Don't want close texts? An alarm rule on the email wording can drop any email that says CLOSED.
Tips for utility alarm texts
A few rules keep the right crew's phone lighting up.
Call lists by service area
If crews cover different towns or districts, a rule can read the substation name and text that area's crew.
Nights and weekends
On-call routing sends after-hours alarms to the person on call and daytime alarms to the operations office.
RTU comm fail to the day crew
A comm fail at a station with a backup path can wait for morning. Send it to the day crew only.
If a QEI alarm doesn't reach the phone
Check these in order.
0 of 4 done
Frequently asked questions
Does Welco connect to the QEI master station directly?
Can a breaker trip text both the crew and the operations manager?
Does a powerline technician's reply acknowledge the alarm at the console?
Will customers ever get these texts?
What if the on-call technician is out of cell coverage?
Can we keep our after-hours callout service too?
How are QEI alarm texts priced?
Send QEI breaker alarms to the crew on call
Give the master station one more email address and the next trip arrives as a text.
7-day free trial, 15 message creditsCard required for verificationNo charge for 7 daysEmail reminder before billing